harmony 鸿蒙Peripheral Management Module Changelog
Peripheral Management Module Changelog
cl.usbddk.1 Change in the USB_DDK/HID_DDK Error Code Definition
Access Level
Public API
Reason for Change
The existing error codes of the peripheral management module may affect user experience in the following scenarios:
Error codes are not defined. When an undefined error code is returned, no effective handling guide is available.
There is no mapping error for an error code, and the error code needs to be deprecated.
Therefore, the involved error codes need to be rectified.
Change Impact
This change is a non-compatible change.
Possible impacts:
After the definition of existing error codes is standardized, you need to verify the error codes again.
For existing undefined error codes, you need to add error code verification and handling measures.
USB error codes
Before Change | After Change |
---|---|
USB_DDK_SUCCESS = 0 | Unchanged |
USB_DDK_FAILED = -1 | Deprecated |
USB_DDK_INVALID_PARAMETER = -2 | USB_DDK_INVALID_PARAMETER = 401 |
USB_DDK_MEMORY_ERROR = -3 | USB_DDK_MEMORY_ERROR = 27400001 |
USB_DDK_INVALID_OPERATION = -4 | USB_DDK_INVALID_OPERATION = 27400002 |
USB_DDK_NULL_PTR = -5 | Deprecated |
USB_DDK_DEVICE_BUSY = -6 | Deprecated |
USB_DDK_TIMEOUT = -7 | USB_DDK_TIMEOUT = 27400004 |
USB_DDK_NO_PERM = 201 | Added |
USB_DDK_IO_FAILED = 27400003 | Added |
HID error codes
Before Change | After Change |
---|---|
HID_DDK_SUCCESS = 0 | Unchanged |
HID_DDK_NO_PERM = -6 | HID_DDK_NO_PERM = 201 |
HID_DDK_INVALID_PARAMETER = -2 | HID_DDK_INVALID_PARAMETER = 401 |
HID_DDK_FAILURE = -1 | HID_DDK_FAILURE = 27300001 |
HID_DDK_NULL_PTR = -4 | HID_DDK_NULL_PTR = 27300002 |
HID_DDK_INVALID_OPERATION = -3 | HID_DDK_INVALID_OPERATION = 27300003 |
HID_DDK_TIMEOUT = -5 | HID_DDK_TIMEOUT = 27300004 |
Start API Level
10
Change Since
OpenHarmony SDK 5.0.0.52
Key API/Component Changes
drivers/external_device_manager
Adaptation Guide
Developers do not need to perform additional adaptation. If specific error codes need to be verified, view the latest error code definition.
You are advised to verify the enum macros instead of the defined enum values when verifying the error codes.
The following is an example of verifying the error code for the HID permission error:
//...
int32_t ret;
ret = OH_Hid_CreateDevice(hidDevice, hidEventProperties);